Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 354
Filtrar
2.
Rev Bras Enferm ; 75(4): e20210967, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36169557

RESUMO

OBJECTIVES: to estimate incidence and free time of peripherally inserted central catheter obstruction in newborns undergoing red blood cell transfusion in the first 24 hours after the procedure. METHODS: a longitudinal study, carried out with neonates in Neonatal Intensive Care Unit at a teaching hospital in Paraná, between January and July 2019. The sample consisted of 46 transfusion events performed in neonates through a peripherally inserted central catheter. Analysis performed according to descriptive statistics. RESULTS: thirty-one catheters were analyzed, inserted in 24 neonates, through which 46 red blood cell transfusions were performed. Most neonates were male, gestational age <32 weeks, weight <1,500 grams, hospitalized mainly for prematurity. Among the 31 catheters, one (3.2%) presented obstruction after transfusion. CONCLUSIONS: The occurrence of obstructions immediately after transfusion was low and the catheters remained complication free for the next 24 hours.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Periférico , Obstrução do Cateter , Infecções Relacionadas a Cateter/epidemiologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Transfusão de Eritrócitos/efeitos adversos , Feminino , Humanos , Lactente , Recém-Nascido , Estudos Longitudinais , Masculino
3.
Br J Nurs ; 31(14): S6-S16, 2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35856577

RESUMO

BACKGROUND: Despite the increasing popularity of midline catheters, data on the use of alteplase for restoring midline catheter patency is scarce. AIMS: This study aimed to evaluate off-label use of alteplase for midline catheter occlusions. METHOD: Adults who received alteplase into a midline catheter between January 2015 and May 2018 within a multi-hospital health system were included in this study. The primary outcome was restoration of infusion or withdrawal function from at least one lumen of a treated midline catheter. FINDINGS: Following alteplase administration, withdrawal function was restored in 47% (25/53) of occlusion events, infusion function was restored in 65% (11/17) of complete occlusion events, and infusion or withdrawal function was restored in 58% (31/53) of occlusion events. Only 34% (17/50) of catheters were replaced because of malfunction. Local bleeding was documented in 9% (n=5) of occlusion events after alteplase administration. CONCLUSION: Most midline catheter occlusions treated with alteplase demonstrated restoration of infusion or withdrawal function.


Assuntos
Cateterismo Venoso Central , Doenças Vasculares , Adulto , Obstrução do Cateter , Fibrinolíticos/uso terapêutico , Humanos , Estudos Retrospectivos , Ativador de Plasminogênio Tecidual/uso terapêutico
4.
Rev Bras Enferm ; 75(5): e20210418, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35584422

RESUMO

OBJECTIVE: to evidence the use of flushing to prevent complications from intravenous therapy. METHODS: an integrative review in databases, using descriptors and selection criteria. Data were collected in 12 articles using an instrument and later classified, summarized and aggregated for knowledge synthesis. RESULTS: it was evident that: the pre-filled syringe resulted in a lower occurrence of catheter obstruction; irregular flushing frequency caused advanced phlebitis; the use of Venous Arterial Blood Management Protection (VAMP) generated a lower incidence of blood infection; heparinized solution did not result in a lower central catheter failure rate; flushing volume and frequency were not predictors of catheter failure; flushing practice was not shown to be incorporated among professionals. CONCLUSION: there are disagreements about the volume, frequency, solution and devices used in flushing. New technologies can reduce complications such as obstruction and infection.


Assuntos
Infecções Relacionadas a Cateter , Administração Intravenosa , Adulto , Obstrução do Cateter , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Infecções Relacionadas a Cateter/prevenção & controle , Hospitalização , Humanos
5.
J Chin Med Assoc ; 85(1): 114-119, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34407037

RESUMO

BACKGROUND: The totally implanted vascular access device (TIVAD) is commonly used in patients with malignant tumors requiring chemotherapy or long-term intravenous infusion and those with difficulty placing peripheral venous catheters. It could also be used to draw blood in pediatric patients. Thus, how to maintain the patency and longevity of TIVAD is always emphasized. METHODS: In this prospective study, TIVAD was randomly infused in patients under 18 years with three different concentrations of heparinized solutions: 10 mL with 100 U/mL heparin, 20 mL with 10 U/mL heparin, and 30 mL with 10 U/mL heparin. RESULTS: A total of 81 patients (46 males and 35 females) were enrolled in this study from August 2, 2013 to February 1, 2017. The mean age of those who received TIVAD implantation was 7.2 ± 5.3 years, and the mean duration of using TIVAD was 1027.6 ± 369.1 days. Patients without catheter occlusion events experienced significantly shorter hospitalizations, fewer admissions, and fewer punctures than those with catheter occlusion events (p < 0.05). The administration and frequency of blood transfusions, history of bacteremia, and medication history did not increase the risk of catheter occlusion, but puncture frequency increased this risk. In patients with catheter occlusion events (38/81, 46.9%), catheter patency was restored after instillation of urokinase solution. CONCLUSION: In this study, the risk of TIVAD catheter occlusion was only related to puncture frequency regardless of the heparin flush composition or patient characteristics. A high puncture frequency of TIVAD during the 3.5-year study period significantly increased the risk of catheter occlusion. Besides, flushing and locking solutions for TIVAD using heparin at 10 U/mL was effective as using heparin at 100 U/mL regardless of the flushing volume of 10, 20, or 30 mL.


Assuntos
Obstrução do Cateter , Neoplasias , Dispositivos de Acesso Vascular , Criança , Pré-Escolar , Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos
6.
BMC Cardiovasc Disord ; 21(1): 502, 2021 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-34663211

RESUMO

BACKGROUND: Leadless pacemaker was a promising innovation than traditional transvenous pacemaker, the procedural complications were prone to be bleeding-related. However, very few reports also concerned about the thrombus formation during the procedure. CASE PRESENTATION: A hemodialysis patient with diabetic gangrene of right foot suffered from catheter-related thrombosis during leadless pacing, resulting in failure of recapture the pacemaker. A low activated clotting time (ACT) level of 104 s confirmed the insufficiency of anticoagulation. Finally, the whole delivery catheter had to be removed from the delivery sheath, another new pacemaker system was applied and successfully implanted after adjusting the ACT level to 248 s. CONCLUSION: Catheter-related thrombosis could be a large obstacle for leadless pacemaker implantation. In addition to routine anticoagulation, ACT monitoring might be necessary during the procedure.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Obstrução do Cateter/etiologia , Cateterismo/efeitos adversos , Cateteres/efeitos adversos , Falência Renal Crônica/terapia , Marca-Passo Artificial , Diálise Renal , Trombose/etiologia , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Coagulação Sanguínea/efeitos dos fármacos , Cateterismo/instrumentação , Monitoramento de Medicamentos , Desenho de Equipamento , Humanos , Falência Renal Crônica/sangue , Falência Renal Crônica/diagnóstico , Masculino , Trombose/sangue , Trombose/diagnóstico , Trombose/prevenção & controle , Tempo de Coagulação do Sangue Total
7.
Lancet Haematol ; 8(9): e637-e647, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34450101

RESUMO

BACKGROUND: 2 billion peripheral intravenous catheters (PIVC) are inserted into inpatients worldwide each year. Almost one in two PIVCs fail before completion of intravenous therapy. We aimed to determine the efficacy and costs of a multimodal intervention to reduce PIVC failure among hospitalised patients. METHODS: PREBACP was a cluster-randomised, controlled trial done at seven public hospitals in Spain. Clusters (hospital wards) had at least 70% permanent staff and data were collected from patients aged 18 years and older with one or more PIVCs at the start of intravenous therapy. Clusters were randomly assigned (1:1) to the multimodal intervention or control group using a centralised, web-based randomisation software, and stratified by type of setting. We concealed randomisation to allocation, without masking patients or professionals to the intervention. An intervention using a multimodal model and dissemination of protocols, education for health-care professionals and patients, and feedback on performance was implemented for 12 months in the intervention group. The control group received usual care. The primary outcome was all-cause PIVC failure at 12 months (phlebitis, extravasation, obstruction, or infections). Subsequently, through an amendment to the protocol approved on July 25, 2021, we included dislodgement as part of PIVC failure. Analysis was by modified intention to treat, which included all randomly assigned hospital wards for whom data on the primary endpoint were available. This trial is registered with the ISRCTN Registry, ISRCTN10438530. FINDINGS: Between Jan 1, 2019, and March 1, 2020, we randomly assigned 22 eligible clusters to receive the multimodal intervention (n=11 clusters; 2196 patients, 2235 PIVCs, and 131 nurses) or usual practice in the control group (n=11 clusters; 2282 patients, 2330 PIVCs, and 138 nurses). At 12 months, the proportion of PIVC failures was lower in the intervention group than in the control group (37·10% [SD 1·32], HR 0·81 [95% CI 0·72 to 0·92] vs 46·49% [2·59], HR 1·23 [1·04 to 1·39]; mean difference -9·39% [95% CI -11·22 to -7·57]; p<0·0001). Per-protocol-prespecified analysis of the primary outcome excluding dislodgement also showed the intervention significantly reduced PIVC failure compared with the control group at 12 months (33·47% [SD 2·98], HR 0·85 [95% CI 0·75 to 0·96] vs 41·06% [4·62], HR 1·18 [1·04 to 1·33]; mean difference -7·59% [95% CI -11·05 to -4·13]; p<0·0001). INTERPRETATION: A multimodal intervention reduced PIVC failure, thereby reducing potentially serious complications for hospitalised patients. The findings of PREBACP enabled a deeper understanding of decision making, knowledge mobilisation, and sense making in routine clinical practice. FUNDING: The College of Nurses of the Balearic Islands. TRANSLATION: For the Spanish translation of the abstract see Supplementary Materials section.


Assuntos
Infecções Relacionadas a Cateter/etiologia , Cateterismo Periférico/efeitos adversos , Flebite/etiologia , Adulto , Idoso , Obstrução do Cateter/etiologia , Cateterismo Periférico/métodos , Feminino , Hospitais Públicos , Humanos , Masculino , Modelos de Riscos Proporcionais , Espanha
8.
World Neurosurg ; 155: e294-e300, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34418611

RESUMO

OBJECTIVE: Occlusion of ventriculoperitoneal shunts placed after intraventricular hemorrhage occurs frequently. The objective of this study was to develop a hemorrhagic hydrocephalus model to assess the ability of an oscillating microactuator within the ventricular catheter (VC) to prevent shunt obstruction. METHODS: An in vitro hydrocephalus model with extreme risk of shunt obstruction was created. Phosphate-buffered saline, blood, and thrombin were driven through ventriculoperitoneal shunts for 8 hours. Five VCs were fitted with a microactuator and compared with 5 control VCs. The microactuator was actuated by an external magnetic field for 30 minutes. Pressure within the imitation lateral ventricle was measured. RESULTS: In the 5 control shunts, 6 obstructions developed (3 VC, 3 valve-distal catheter) compared with 1 obstruction (VC) in the 5 microactuator shunts. In the control and microactuator groups, the median volume exiting the shunts in 8 hours was 30 mL versus 256 mL. Median time to reach an intraventricular pressure of 40 mm Hg (13.8 minutes vs. >8 hours), median total time >40 mm Hg (6.2 hours vs. 0.0 hours), and median maximum pressure (192 mm Hg vs. 36 mm Hg) were significantly improved in the microactuator group (P < 0.01). CONCLUSIONS: In addition to protecting the VC, the microactuator appeared to prevent hematoma obstructing the valve or distal catheter, resulting in a much longer duration of low intraventricular pressures. A microactuator activated by placing the patient's head in an external magnetic field could reduce shunt obstructions in hemorrhagic hydrocephalus.


Assuntos
Obstrução do Cateter , Hemorragia Cerebral/cirurgia , Análise de Falha de Equipamento/instrumentação , Hidrocefalia/cirurgia , Campos Magnéticos , Derivação Ventriculoperitoneal/instrumentação , Animais , Obstrução do Cateter/efeitos adversos , Hemorragia Cerebral/complicações , Análise de Falha de Equipamento/métodos , Hidrocefalia/etiologia , Modelos Biológicos , Projetos Piloto , Suínos , Derivação Ventriculoperitoneal/efeitos adversos
9.
Fluids Barriers CNS ; 18(1): 33, 2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34289858

RESUMO

BACKGROUND: Implantation of ventricular catheters (VCs) to drain cerebrospinal fluid (CSF) is a standard approach to treat hydrocephalus. VCs fail frequently due to tissue obstructing the lumen via the drainage holes. Mechanisms driving obstruction are poorly understood. This study aimed to characterize the histological features of VC obstructions and identify links to clinical factors. METHODS: 343 VCs with relevant clinical data were collected from five centers. Each hole on the VCs was classified by degree of tissue obstruction after macroscopic analysis. A subgroup of 54 samples was analyzed using immunofluorescent labelling, histology and immunohistochemistry. RESULTS: 61.5% of the 343 VCs analyzed had tissue aggregates occluding at least one hole (n = 211) however the vast majority of the holes (70%) showed no tissue aggregates. Mean age at which patients with occluded VCs had their first surgeries (3.25 yrs) was lower than in patients with non-occluded VCs (5.29 yrs, p < 0.02). Mean length of time of implantation of occluded VCs, 33.22 months was greater than for non-occluded VCs, 23.8 months (p = 0.02). Patients with myelomeningocele had a greater probability of having an occluded VC (p = 0.0426). VCs with occlusions had greater numbers of macrophages and astrocytes in comparison to non-occluded VCs (p < 0.01). Microglia comprised only 2-6% of the VC-obstructing tissue aggregates. Histologic analysis showed choroid plexus occlusion in 24%, vascularized glial tissue occlusion in 24%, prevalent lymphocytic inflammation in 29%, and foreign body giant cell reactions in 5% and no ependyma. CONCLUSION: Our data show that age of the first surgery and length of time a VC is implanted are factors that influence the degree of VC obstruction. The tissue aggregates obstructing VCs are composed predominantly of astrocytes and macrophages; microglia have a relatively small presence.


Assuntos
Obstrução do Cateter/efeitos adversos , Cateteres de Demora/efeitos adversos , Plexo Corióideo/patologia , Hidrocefalia/cirurgia , Derivação Ventriculoperitoneal/efeitos adversos , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Plexo Corióideo/citologia , Feminino , Humanos , Hidrocefalia/diagnóstico , Imageamento Tridimensional/métodos , Lactente , Masculino , Estudos Retrospectivos , Fatores de Tempo , Derivação Ventriculoperitoneal/tendências , Adulto Jovem
10.
J Control Release ; 336: 1-15, 2021 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-34118339

RESUMO

Continuous intraperitoneal insulin infusion, from an implanted insulin pump connected to a catheter that delivers insulin directly to the peritoneal cavity has many clinical advantages for patients with Type 1 diabetes. However, the ongoing incidence of catheter obstructions remains a barrier to the widespread use of this therapy. To date, the root cause of these obstructions remains unknown. Here, a two-year clinical investigation was conducted, along with the development of an animal model to enable a mechanistic investigation into this issue. This novel animal model was able to mimic the catheter obstructions that occur in patients and, fortuitously, at an accelerated rate. This model allowed for independent assessment of each potential cause associated with catheter obstructions to help identify the root cause. Both macroscopic and microscopic analysis were conducted with regards to the onset and progression of catheter obstructions, along with monitoring of insulin delivery. Interestingly, although insulin aggregation occurs in insulin pumps and insulin aggregates were found in some catheter obstructions, insulin is unlikely to be the root cause, since obstructions also occurred in the control groups where only diluent (no insulin) was administered to the animals. Inflammatory cells, different phenotypes of fibroblasts, as well as collagen were observed in all obstructed catheters explanted from the patients and the animals. The presence of these cells and collagen is indicative of a typical foreign body reaction. In addition, the dynamic change in the fibroblasts with respect to morphology, phenotype, and spatial distribution suggests that tissue irritation-mediated epithelial to mesenchymal transition plays a role in catheter obstructions.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Obstrução do Cateter , Diabetes Mellitus Tipo 1/tratamento farmacológico , Transição Epitelial-Mesenquimal , Reação a Corpo Estranho/induzido quimicamente , Humanos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
11.
BJU Int ; 128(6): 667-677, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33811741

RESUMO

OBJECTIVE: To look at best evidence and expert opinion to provide advice in the form of a consensus statement lead by Female, Neurological and Urodynamic Urology (FNUU) section of the British Association of Urological Surgeons (BAUS) in conjunction with the British Association of Urological Nurses (BAUN). METHODS: Initially a literature search was performed with incorporation of aspects of the existing guidance and further informed by UK best practice by core members of the group. The document then underwent reviews by the FNUU Executive Committee members, the BAUN executive committee, a separate experienced urologist and presented at the BAUS annual meeting 2020 to ensure wider feedback was incorporated in the document. RESULTS: Complications of long-term indwelling catheters include catheter-associated urinary tract infections (CAUTI), purple urine bag syndrome, catheter blockages, bladder spasms (causing pain and urinary leakage), loss of bladder capacity, urethral erosion ("catheter hypospadias")/dilatation of bladder outlet and chronic inflammation (metaplasia and cancer risk). CONCLUSIONS: We have provided a list of recommendations and a troubleshooting table to help with the management of the complications of long term catheters.


Assuntos
Obstrução do Cateter/etiologia , Infecções Relacionadas a Cateter/terapia , Cateteres de Demora/efeitos adversos , Doenças da Bexiga Urinária/terapia , Cateteres Urinários/efeitos adversos , Infecções Urinárias/terapia , Infecções Relacionadas a Cateter/etiologia , Consenso , Humanos , Metaplasia/etiologia , Necrose/etiologia , Necrose/prevenção & controle , Espasmo/etiologia , Irrigação Terapêutica , Fatores de Tempo , Uretra/patologia , Bexiga Urinária/patologia , Doenças da Bexiga Urinária/etiologia , Infecções Urinárias/etiologia
12.
Rev. ecuat. pediatr ; 22(1): 1-7, Abril 30, 2021.
Artigo em Inglês | LILACS | ID: biblio-1222350

RESUMO

Introduction: Advances in the management and survival of severe pediatric disease have led to an increase in thromboembolic phenomena, given the frequent need for central venous catheters (CVC). The present study describes the conditions in which venous thrombosis oc-curs in pediatric patients with CVC in a public referral center in Guayaquil. Methods: This is an observational, cross-sectional study with the objective of identifying fac-tors that are associated with the development of venous thrombosis in patients with CVC ad-mitted to the Intensive Care Unit. Information was collected in a pre-designed chart of all patients with CVC for more than 7 days. A venous Doppler ultrasound was performed to de-termine the presence or absence of thrombi. Descriptive statistics were used for univariate analysis and Odds Ratio was used for the bivariate analysis. Results: 35 patients were included in the study, 14/35 (40%) young infants, 24/35 males (69%), 19 cases (54%) with malnutrition, 10 cases (29%) with congenital heart disease, and 18 cases (51%) admitted for infections. The puncture site was femoral in 11 cases (31%), the procedure was performed by the fellow in 20 cases (57%), on a scheduled basis in 27 cases (77%), and performed in a single attempt in 28 cases (80%). The tip of the catheter was located in the superior vena cava in 23 cases (66%). The prevalence of thrombosis was 14% (95% CI 12.33-16.25). Bivariate analysis showed that none of the variables were associated with the presence of CVC thrombosis. Conclusions: 14% of patients with CVC use for more than 7 days develop secondary venous thrombosis. The factors associated with CVC including nutritional status and related proce-dures could not be determined.


Assuntos
Criança , Infecções Relacionadas a Cateter , Cateteres , Obstrução do Cateter
13.
Nutr Clin Pract ; 36(4): 872-876, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33624392

RESUMO

BACKGROUND: Children with intestinal failure (IF) require parenteral nutrition (PN) at home, delivered through a central venous catheter (CVC) to support growth. CVC-related complications including infection, breakage, and blockage are the most common cause of readmission to the hospital. The objective of this study was to evaluate the use of instructional videos as part of the caregiver home PN-teaching program to reduce CVC-related complications. METHODS: Caregivers of children with IF requiring home PN were surveyed to assess skill confidence and interest in instructional videos for skill acquisition. Videos were then created using a smartphone and free video-editing software. Input from stakeholders (families, care providers) was incorporated in video production. Families were given access to the videos, and CVC-related complications were compared for 2 years prior to and 1 year following video introduction with Welch t-test analysis. RESULTS: After obtaining ethics approval, 11 caregivers were surveyed. Thirty percent reported feeling underconfident in their skills at the time of discharge. After viewing the videos, 100% of caregivers reported that these videos were useful. Catheter-related complication rates significantly decreased in the year following the video introduction from 7.88 to 2.65 complications per 1000 catheter days (P = .046). This included reductions in catheter-related infections, catheter occlusions, and breakages. CONCLUSIONS: Children with IF receiving home PN are at high risk for CVC-related complications, and caregivers are the first line of defense for catheter care. Instructional videos were low-cost to create, were well received by all families, and may contribute to reduced catheter-related complications.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateteres Venosos Centrais , Nutrição Parenteral no Domicílio , Obstrução do Cateter , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Criança , Humanos , Nutrição Parenteral no Domicílio/efeitos adversos , Estudos Retrospectivos
14.
J Hosp Infect ; 111: 69-77, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33545216

RESUMO

BACKGROUND: Up to 50% of all long-term catheterized individuals experience recurrent episodes of urinary catheter infections and blockages, leading to urine retention, pyelonephritis and septicaemia if the catheter is left in situ. We have previously reported the synergistic activity of weak organic acid (WOA) combinations against nosocomial uropathogens. AIM: To investigate the efficacy of selected WOAs, citric acid and propionic acid, alone and in combination, on prevention of crystalline biofilm formation and catheter blockages. METHODS: Static crystallization assays and dynamic in vitro bladder model assays, with scanning electron microscopy, were performed for determination of bacterial viability, urinary pH and time to catheter blockage. FINDINGS: The rate of encrustation around the catheter eyeholes was reduced in the presence of the citric acid/propionic acid combination, extending the time to blockage three-fold. CONCLUSION: Synergistic WOA combinations identified herein represent promising alternatives to antibiotics to combat the global healthcare burden of catheter-associated urinary tract infections and related blockages.


Assuntos
Obstrução do Cateter , Ácido Cítrico/farmacologia , Propionatos/farmacologia , Cateterismo Urinário , Infecções Urinárias , Biofilmes , Cateteres de Demora , Humanos , Microscopia Eletrônica de Varredura , Infecções Urinárias/prevenção & controle
15.
Clin Nutr ; 40(6): 4263-4266, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33551216

RESUMO

INTRODUCTION: Patients with chronic intestinal failure (IF) require home parenteral nutrition (HPN). Central venous access is needed for prolonged use of PN, usually via a long term central venous access device (CVAD). Post insertion there may be mechanical complications with a CVAD such as catheter rupture or tear. Repair of damaged CVADs is possible to avoid risks associated with catheter replacement in patients with IF. However, catheter related blood stream infections (CRBSI) are a concern when CVAD's are accessed or manipulated. AIMS: To investigate the success of repair of CVADs in patients with IF on HPN, related to repair longevity and incidence of CRBSI following repair. METHOD: Nutrition team records of CVAD repairs carried out in patients with IF were reviewed retrospectively for the period April 2015 to March 2019. RESULTS: Nutrition Clinical Nurse Specialists carried out 38 repairs in 27 patients. Male n = 5, female n = 22; mean age 55 years. Catheter longevity before first repair (n = 27): median 851 days, IQR 137-1484 days. 30/38 (78.9%) of repairs were successful lasting ≥30days. Hospital admission was avoided in 76% of cases. 4 patients in the failed repair group underwent catheter re-insertion where 4 had a further, subsequently successful, repair, an overall success rate of 89.4% (34/38). 30-day CRBSI rate was 0.09/1000 catheter days in repaired catheters. In comparing costs, there is a potential cost saving of 2766GBP for repair compared to replacement of damaged CVADs. CONCLUSION: Repair of tunnelled CVADs in patients with IF is successful and safe with no increased risk of CRBSI. Significant cost savings may be made.


Assuntos
Obstrução do Cateter/estatística & dados numéricos , Cateterismo Venoso Central/instrumentação , Cateteres Venosos Centrais/efeitos adversos , Insuficiência Intestinal/terapia , Nutrição Parenteral no Domicílio/instrumentação , Obstrução do Cateter/efeitos adversos , Obstrução do Cateter/economia , Infecções Relacionadas a Cateter/economia , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/economia , Cateteres Venosos Centrais/economia , Análise Custo-Benefício , Feminino , Humanos , Insuficiência Intestinal/economia , Masculino , Pessoa de Meia-Idade , Enfermeiras Clínicas/estatística & dados numéricos , Nutrição Parenteral no Domicílio/economia , Estudos Retrospectivos , Resultado do Tratamento
16.
Clin Exp Nephrol ; 25(4): 418-427, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33398602

RESUMO

BACKGROUND: The Moncrief-Popovich technique of peritoneal catheter implantation has beneficial effects for peritoneal dialysis (PD) initiation. However, it might increase the risk of peritoneal catheter obstruction by fibrin clots, because the catheter is buried under the skin for several weeks to months. Effects of treatment of intraluminal occlusion of PD catheters with tissue plasminogen activator, recommended by the International Society for Peritoneal Dialysis guidelines/recommendations are reportedly limited. We investigated the effectiveness of the 'alpha-replacer' (JMS, Tokyo, Japan) for PD catheter obstruction. METHODS: We retrospectively analyzed a total of 193 patients in whom PD was initiated. PD catheters were embedded using the Moncrief-Popovich technique in 130 of these patients. We assessed the occurrence rates of peritoneal catheter obstruction and the utility of the alpha-replacer for treating intraluminal catheter occlusion by fibrin clots. RESULTS: Catheter obstruction occurred in eight cases with embedded catheters, one due to omental wrapping and the others due to fibrin clots, in which median catheter burial durations were 477 (interquartile range [IQR], 226-510) days. All catheter obstructions due to fibrin clots were successfully treated with the alpha-replacer, leading to improved catheter drainage. The median amount of contrast agent used in catheterography was 10 (IQR 9-10) mL, which did not adversely affect residual renal function. There were no complications. No recurrence occurred during the observation period (median 111, IQR 55.5-141 months). CONCLUSION: Our results suggest that treatment with the alpha-replacer is a safe and effective treatment option for intraluminal obstruction of PD catheters by fibrin clots.


Assuntos
Obstrução do Cateter/etiologia , Cateterismo/instrumentação , Cateteres de Demora/efeitos adversos , Fibrina/metabolismo , Nefropatias/terapia , Diálise Peritoneal/instrumentação , Adulto , Idoso , Cateterismo/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Diálise Peritoneal/efeitos adversos , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
17.
Ann Vasc Surg ; 72: 383-389, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32890642

RESUMO

BACKGROUND: Central venous occlusive disease (CVOD) is a prevalent problem in patients with end-stage renal disease (ESRD) and can lead to access malfunction or ligation for symptomatic relief. The purpose of this study is to evaluate the efficacy of the TriForce® Peripheral Crossing Set (Cook Medical), a novel reinforced telescoping catheter set designed to provide additional support for crossing difficult central venous occlusions. METHODS: This is a single-center retrospective study from a quaternary referral center. We identified 37 patients over a 17-month period who underwent 56 attempts at endovascular recanalization for the treatment of central venous occlusion. Technical success rates, procedural data, and outcomes were compared between those undergoing recanalization using traditional wire/catheter sets versus the TriForce catheter set. RESULTS: Average age was 48 ± 2 years. Comorbidities were similar between the two cohorts and included ESRD (61%), deep venous thrombosis (30%), and May-Thurner syndrome (7%). Forty attempts were made with traditional wire/catheter sets and 16 attempts with the TriForce catheter set to treat 2.1 ± 0.2 and 1.9 ± 0.3 occluded venous segments, respectively (P = 0.74). Technical success rates were significantly higher for the group undergoing recanalization using the TriForce catheter (69% versus 38%, P = 0.04) and 4 patients were successfully recanalized using the TriForce catheter set after a failed attempt with traditional wire/catheter sets. Mean fluoroscopy time and radiation dose were 13 ± 3 min and 14,623 ± 2,775 µGy∗m2 for traditional techniques versus 30 ± 6 min and 30,408 ± 10,433 µGy∗m2 for the novel telescoping catheter set (P = 0.01 and 0.09, respectively). Freedom from reintervention at 1 year was 60% for the TriForce cohort versus 44% for the traditional wire/catheter cohort (P = 0.25). CONCLUSIONS: The novel TriForce reinforced telescoping catheter set is a useful adjunct that may improve recanalization rates of CVOD compared with traditional wire/catheter sets.


Assuntos
Procedimentos Endovasculares/instrumentação , Dispositivos de Acesso Vascular , Doenças Vasculares/terapia , Veias , Obstrução do Cateter , Cateterismo Venoso Central/efeitos adversos , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia , Grau de Desobstrução Vascular , Veias/diagnóstico por imagem , Veias/fisiopatologia
18.
Cardiovasc Pathol ; 50: 107299, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33080399

RESUMO

In the setting of HeartWare left ventricular assist device (HVAD, Medtronic) implantation, pre-pump blood flow obstruction has been described due to intraventricular thrombus formation occluding the inflow cannula. This phenomenon often evolves in suboptimal pump performance, and requires prompt management to prevent its progression. However, to date, effective strategies and tools for the diagnosis and management of this complication are poorly described. We report a case of HVAD inflow cannula obstruction that drove later in-pump thrombosis and, eventually, complete cannula occlusion, and discuss gap of knowledge and limitations of currently available diagnostic and therapeutic tools in this scenario. Furthermore, we reinforce the value of time-frequency analysis of the HVAD log files to early identify abnormal pump operation associated with inflow cannula obstruction despite unremarkable trends of pump parameters.


Assuntos
Obstrução do Cateter , Insuficiência Cardíaca/terapia , Coração Auxiliar , Falha de Prótese , Trombose/etiologia , Função Ventricular Esquerda , Diagnóstico Precoce , Evolução Fatal , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Trombose/diagnóstico , Trombose/terapia , Resultado do Tratamento
19.
J Vasc Access ; 22(3): 359-363, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32667243

RESUMO

PURPOSE: This study examined the safety and efficacy of placing both a central venous dialysis catheter and a central venous catheter for infusion in the right internal jugular vein compared to only a central venous dialysis catheter. METHODS: We conducted a retrospective chart review for all adult patients who underwent the placement of the right internal jugular dialysis catheter by a single surgeon. Patients were grouped based on whether they received a tunneled dual lumen dialysis catheter alone or in combination with a central venous infusion catheter in the right internal jugular vein. Catheter-related thrombosis, line infections, line malfunctions, pneumothorax, and need for line replacement were evaluated. RESULTS: There were 97 patients in the dialysis catheter and central venous infusion line group and 63 patients in the dialysis catheter only group. The two groups were not different with regard to age (62.1 ± 16.3 years vs 57.9 ± 17.6 years) and gender (47.4% male vs 55.6% male). No significant differences were found in the incidence of thrombosis (1.0 % vs 0.0%, p > 0.999), line infection (2.1% vs 0.0%, p = 0.519), or line malfunctions (2.1% vs 0.0%, p = 0.516) in patients who did or did not have a central venous infusion catheter placed concomitantly with the dialysis catheter, respectively. No patients in either group had a pneumothorax. CONCLUSIONS: Although not currently utilized with frequency, these preliminary data indicate that placing both a dual lumen dialysis catheter and central venous infusion catheter in the right internal jugular simultaneously could be a viable option.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Diálise Renal/instrumentação , Adulto , Idoso , Obstrução do Cateter/etiologia , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Remoção de Dispositivo , Feminino , Humanos , Infusões Intravenosas , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Trombose Venosa/etiologia
20.
Cancer Nurs ; 44(3): 205-213, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32384421

RESUMO

BACKGROUND: Flushing and locking of totally implantable venous access devices (TIVADs) is recommended to maintain their patency when not in use. Although manufacturers' recommendations indicate monthly access for TIVAD maintenance, there is a tendency in real life to prolong this interval. OBJECTIVES: To assess the effectiveness of prolonged versus short flushing and locking intervals to prevent TIVAD occlusions in adults with cancer. METHODS: A systematic search was carried out in MEDLINE, EMBASE, CINAHL, and Web of Science. Two reviewers independently selected studies, assessed quality, and extracted data. Study findings were summarized, and a meta-analysis conducted. RESULTS: Six articles were included in the review, with a total of 1255 participants. Differences in types of cancers, flushing and locking techniques, and volume and concentration of heparin were described. Pooled results from 4 studies showed fewer catheter occlusions in favor of prolonged flushing and locking intervals (relative risk, 0.81), even if not statistically significant (95% confidence interval, 0.41-1.61) with no heterogeneity among studies (I2 = 0.00%, P = .69). The quality of evidence was very low. CONCLUSIONS: Very low-quality evidence suggests that prolonged schedule flushing and locking intervals has no effect on catheter patency. However, because of low number and poor quality of evidence derived from the studies analyzed, findings of this meta-analysis should be interpreted with caution. IMPLICATIONS FOR PRACTICE: No statistically significant difference in occlusion rate between short and long timing of flushing was found. However, further studies are necessary to strengthen the safe implementation of longer intervals in clinical practice.


Assuntos
Obstrução do Cateter/efeitos adversos , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres Venosos Centrais/efeitos adversos , Heparina/efeitos adversos , Humanos , Neoplasias/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...